<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>39508</ErrorNumber>
<ErrorFamily>I/O Scanner</ErrorFamily>
<ErrorMessage>
IOS: Bypass not allowed on this I/O
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_400_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_800_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
An attempt was made to set a bypass status for either a discrete I/O
point or a group input (Analog input) for which bypassing is not allowed
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The I/O point can't be bypassed.  The original problem leading to the
bypass attempt must be rectified.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Most systems contain air-driven devices.  To the firmware, they all work
in a similar manner.  They are stable at either position 'A' or 'B' as
indicated by the state of discrete sensors at these positions.  In these
cases the sensors supplies only final verification of a blind actions against
hard mechanical stops.  If these sensors malfunction, they may be bypassed
(temporarily) to allow the machine to continue with a diminished throughput.
Sensors associated with stepper motors or plate length measurement are used
in real-time control and may not be bypassed.  An attempt to set bypass status
for one of these types of sensor results in this error
</Cause>
<LastModified>
08-JAN-2001
Automated conversion to new FW1 error template.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:20 2008 PST
</Updated>
<Links>
</Links>
</Error>